BEP Control 1 interface CZone
Description
CZone Control 1 Interface
The Control 1 Interface combines multiple input and output devices into one module. This minimizes time and effort during installation by reducing connections between multiple modules and the footprint required. The Control 1 Interface incorporates many of the core features and benefits of the fully featured Combination Output Interface (COI), but has been re-engineered to offer improved cost-per-channel value. The Control 1 Interface features the same rugged design as the fully featured COI with IPx5 water ingress protection and complete mechanical fuse and bypass on all circuits. Industry standard Deutsch connectors provide reliable plug and play installation.
Control 1 Interface builds onto CZone’s portfolio of leading digital control and monitoring products. Delivering only the essential features required for small systems, the Control 1 Interface increases affordability and ensures the benefits of CZone are accessible to a wider range of applications than ever before.
Output channels (high) |
4 x 25 A |
Output channels (low) |
12 x 10 A (dimmable) |
Analogue inputs |
8 inputs (positive or negative switching, 0-32 V), 0-1000 Ohm resistance, 4-20 mA current |
Communication protocol |
NMEA 2000 |
NMEA 2000 PGN output |
fluid Level, pressure, temperature, battery voltage |
Circuit current monitoring |
no |
Circuit protection |
ATC fuse with fuse tripped & fuse in bypass alarms |
Additional monitoring |
1x voltage sense on main positive stud |
Circuit bypass |
mechanical protection / bypass all output channels |
Max. continuous current |
150 A at 40 °C / 104 °F (derating > 40 °C / 104 °F) |
Connectors |
Deutsch |
Power supply |
M8 (5/16”) stud positive, M6 (1/4”) stud negative |
Supply voltage |
9-32 V (with power available LED) |
Bilge pump circuits |
4 high current channels: integrated manual control and 'pump running' detection |
Protection degree |
IPx5 (mounted at 0° +/- 90°) |
Dimensions hxwxd |
339 x 194 x 65 mm |
Weight |
1.9 kg |
Approvals |
CE, ABYC, NMEA, ISO8846/SAEJ1171 Ignition Protected |
Power consumption |
operating (all channels On) = 100 mA at 13.2 V / operating (all channels Off ) = 75 mA at 13.2 V |
-
General Specification
Output channels (high)
4 x 25 A
Output channels (low)
12 x 10 A (dimmable)
Analogue inputs
8 inputs (positive or negative switching, 0-32 V), 0-1000 Ohm resistance, 4-20 mA current
Communication protocol
NMEA 2000
NMEA 2000 PGN output
fluid Level, pressure, temperature, battery voltage
Circuit current monitoring
no
Circuit protection
ATC fuse with fuse tripped & fuse in bypass alarms
Additional monitoring
1x voltage sense on main positive stud
Circuit bypass
mechanical protection / bypass all output channels
Max. continuous current
150 A at 40 °C / 104 °F (derating > 40 °C / 104 °F)
Connectors
Deutsch
Power supply
M8 (5/16”) stud positive, M6 (1/4”) stud negative
Supply voltage
9-32 V (with power available LED)
Bilge pump circuits
4 high current channels: integrated manual control and 'pump running' detection
Protection degree
IPx5 (mounted at 0° +/- 90°)
Dimensions hxwxd
339 x 194 x 65 mm
Weight
1.9 kg
Approvals
CE, ABYC, NMEA, ISO8846/SAEJ1171 Ignition Protected
Power consumption
operating (all channels On) = 100 mA at 13.2 V / operating (all channels Off ) = 75 mA at 13.2 V