FIREBOY-XINTEX
Fireboy-Xintex provides a variety of reliable, trouble-free fire detection, fire suppression and gas
detection products. Fireboy-Xintex specializes in total flooding clean agent fire suppression systems utilizing either 3M™ Novec™ 1230 fire protection fluid or Dupont™ FM200® fire extinguishant. They offer both pre-engineered and custom engineered fire safety systems.
Fire suppression systems:
1) Engineered Fire Suppression:
An engineered system utilizing a fixed nozzle agent distribution network, the system is designed and installed in accordance with the IMO FSS CODE (SOLAS, IMO MSC/Circ.1267 “Clean Agent Fire Extinguishing Systems”).
When properly designed, the HFC-227ea fire extinguishant system will suppress surface burning fire in Class A, B, and C hazards.
80% of HFC-227ea fire extinguishant firefighting effectiveness is achieved through heat absorption and 20% through direct chemical means (action of the fluorine radical on the chain reaction of a flame.
Complete suppression using HFC-227ea fire extinguishant has the following advantages:
• The low concentration of HFC-227ea fire extinguishant required means less visual obscurity and minimal risk to personnel.
• The small quantity of agent discharged minimizes over-pressurization of the protected area.
• Maximum safety for personnel due to low toxicity.
• The ability to prevent re-ignition as long as concentration levels are maintained.
2) FES System
An engineered system utilizing a fixed nozzle agent distribution network, the system is designed and installed in accordance with the IMO FSS CODE (SOLAS, IMO MSC/Circ.1267 “Clean Agent Fire Extinguishing Systems”).
When properly designed, the HFC-227ea fire extinguishing system will suppress surface burning fire in Class A, B, and C hazards.
80% of HFC-227ea fire extinguishant firefighting effectiveness is achieved through heat absorption and 20% through direct chemical means (action of the fluorine radical on the chain reaction of a flame.
Complete suppression using HFC-227ea fire extinguishant has the following advantages:
• The low concentration of HFC-227ea fire extinguishant required means less visual obscurity and minimal risk to personnel.
• The small quantity of agent discharged minimizes over-pressurization of the protected area.
• Maximum safety for personnel due to low toxicity.
• The ability to prevent re-ignition as long as concentration levels are maintained.
Note: Engineered fire extinguisher systems not available in catalogue. Please contact Exalto Emirates for design assistance.
3)Total Flooding Pre-Engineered Fire Extinguishing Systems:
Worldwide approved Clean Agent HFC-227ea and 3M™ Novec™ 1230 Fire Protection Fluid.
Fireboy clean agent fire extinguisher systems are designed to automatically discharge whenever the protected space ambient temperature reaches 175 degrees Fahrenheit.
When the Fireboy System discharges, the extinguisher is designed to fully empty the contents in less than 10 seconds. No cleanup is required. There is no powdery residue or water left behind.
The fire is extinguished by a combination of heat reduction and chemical reaction.
Fireboy Systems are available to protect engine rooms and machinery spaces from as small as 25 cubic feet to as large as 3000 cubic feet.
Each Fireboy pre-engineered fire extinguishing system includes stainless steel mounting brackets, helm station status LED panel and Owners/Installation manual.
Backed by a 3-year limited warranty. All Fireboy Extinguishers are factory refillable except when the discharge is the result of a fire.
Total Flooding Pre-Engineered Fire Extinguisher Systems are approved by:
• USCG (MA Series)
• USCG (CG Series)
• ISO RINA
• MCA Certified
• PED BV Final
• Bureau Veritas
• Factory Mutual
All systems meet EN ISO 9094-1 and EN ISO 9094-2 standards
a) Fully Automatic: CG Series
CG Series: Automatic Discharge Fixed Clean Agent Fire Extinguisher
HFC-227ea and 3M™ Novec™ 1230 Models Available
Coverage up to 1000 cu. ft. Protects engine rooms and machinery spaces up to 1000 cubic feet
• Pre-engineered, total flooding system
• The safest way to combat an engine room fire
• Automatic discharge at 175°F (79°C)
• HFC-227ea – effective Halon replacement clean agent
• 3M™ Novec™ 1230 fire protection is more environmentally friendly with a lower global warming potential
• No water or powdery residue
• Includes powder coated mounting bracket and 2 in. helm display
• 3-Year Limited Warranty
• USCG, Factory Mutual, ISO RINA, and Bureau Veritas Approved
b) Automatic/Manual: MA Series
MA Series: Manual / Automatic Discharge Fixed Clean Agent
Fire Extinguisher. HFC-227ea and 3M™ Novec™ 1230 Models Available.
Coverage from 25 to 1,800 cu. ft. Protects engine rooms and machinery spaces up to 1800 cubic feet (with 3M™ Novec™1230)
• Pre-engineered, total flooding system
• The safest way to combat an engine room fire
• Automatic discharge at 175°F (79°C) with optional manual release
• HFC-227ea – effective Halon replacement clean agent
• 3M™ Novec™ 1230
• No water or powdery residue
• Includes locking lever for increased safety when removing or installing cable
• Includes powder coated mounting bracket and 2 in. L.E.D. helm display
• 3-Year Limited Warranty
MA2 Series extinguisher listings and approvals: USCG | ISO RINA| MCA Certified | PED BV Final | Bureau Veritas | Factory Mutual
c) Automatic/Manual: MA Series
GA Series: Large Capacity Automatic / Manual Fire Extinguisher GA Series 600 to 4,000 cu. ft.
HFC-227ea and 3M™ Novec™ 1230 Models Available. Coverage from 600 cu. ft. to 4,000 cu.ft. Designed for larger boats and yachts
• Protection from 600 cu. ft. to 3,000 cu. ft. (2,000 ft³ to 4,000 ft.³ with 3M™ Novec™ 1230
• Pre-engineered, total flooding system
• Single and patented two-cylinder linked system design
• Custom manufactured to order
• No water or powdery residue
• 3-Year Limited Warranty
• USCG, Factory Mutual, ISO RINA, Bureau Veritas Approved
Fireboy’s GA link allows faster and easier installation with double check-valve quick-connects. This is the first pre-engineered system approved by the USCG for volumes over 1,500 cu. ft.
Description: The Fireboy GA Series is a patented, pre-engineered total flooding fire extinguishing system for protecting larger boats with engine rooms from 600 cubic feet to 4,000 cubic feet.
Each system includes:
• Single or twin extinguisher cylinders
• Flexible braided stainless steel hosing
• One or two overhead temperature sensors
• Fire-resistant manual release cables
• Engine shutdown module (sold separately)
Two or four temperature sensors monitor the engine room temperature 24 hours per day. Two of the temperature sensors are located on the manifold blocks of the cylinders. The remaining one or two temperature sensors are installed above the engines and are linked to the extinguisher cylinders with the flexible hosing. When the engine room temperature reaches 175°F (79°C) at any of the temperature sensors, the system will completely discharge the clean agent in less than 10 seconds to successfully extinguish the fire. No residue is left behind. To prevent accidental discharge during shipping and installation, each system is fitted with a patented safety-lock poppet valve. Installation is less costly and less time consuming compared to engineered systems protecting the same volume.
Additionally, no costly third-party certification is required; all certifications are done directly through Fireboy-Xintex. USCG, Factory Mutual, RINA and Bureau Veritas approved.
Each GA Series system is fitted with a “GA Link” which is flexible, braided 316 stainless-steel hosing with double check valve quick-connect couplings for easy attachment/detachment to the cylinder valve. When the system is armed, the link is highly pressurized. If the temperature reaches 175°F (79°C) at any of the temperature sensors, a drop in pressure occurs, triggering discharge of the system. The flexibility of the GA Link allows for easier installation. No complex piping is required as with many engineered CO2 systems, making the GA Series a viable alternative to more costly and labor intensive systems.
Fire detection systems:
Fireboy-Xintex provides fire detection system for Commercial Vessels
(USCG & ABS approved) & for Recreational yachts.
There are 3 types of Fire Detection Systems:
1) Commercial USCG approved vessels: Elite RSM
Elite RSM Marine and Offshore Analog Addressable Fire Alarm Control Panel
Two Loop Panel USCG Type Approved, and ABS Approved, for the protection of accommodation areas and machinery spaces.
Fireboy-Xintex Elite RSM uses leading edge microprocessor technology to provide a flexible control system with high reliability and integrity.
Elite RSM control panels can be expanded and networked to become a flexible control system.
The large graphical display and ergonomic button and indicator layout, the Fireboy-Xintex control panel is simple and straightforward to understand for installers, commissioning personnel, and boaters alike. Control panel has two loops and is
Designed to accommodate 126 smoke and/or heat detectors per loop.
Battery back-up maintains system monitoring even when 24 VDC power is not available.
Repeater Panels are available for installation in key monitoring regions.
2) Recreational yachts: FR Series:
a) FR-1000 (1 zone)
b) FR-2000 (2 zones)
c) FR-4000 (4 zones)
d) FR-8000 (8 zones)
The Fireboy-Xintex Fire Detection Products offer many desirable features and functions in marine fire detection equipment.
FR series provide intelligent networked solutions with easy installation.
The FR Series were designed with the yacht and cabin cruiser customer in mind.
Sleek, compact design in the FR-1000 and FR-2000 Models are encased in 2-5/8″ square front bezel.
Up to 14 smoke and/or heat detectors (12DC system) may be connected to each zone.
Designed for use with the Apollo Series 65 UL Listed detectors.
FR Series fire detectors monitor either 1, 2,4, or 8 zones.
3) Commercial IMO/ Solas Approved: Syncro ASM Series
The Syncro ASM Series meets international standards, IMO / Solas, RINA, BV, GL.
Conforms to FSS Code Ch 9.
This is an analog addressable series with 2 loops capable of 126 smoke or heat detectors per loop.
Designed for use with Apollo Discovery Detectors.
Battery back-up maintains the monitoring even when 240V AC Power is not available.
Repeater Panels are available for installation into key monitoring regions.
Syncro ASM uses leading edge microprocessor technology to provide a flexible control system with high reliability and integrity.
Designed for all small to medium sized vessels, Syncro ASM control panels can be expanded and networked to become a flexible control system.
The large graphical display and ergonomic button and indicator layout, the Syncro ASM control panel is simple and straightforward to understand for installers, commissioning personnel, and boaters alike.
For any of your requirements for the above products please contact Exalto Emirates.
browse PRODUCTS
-
FIREBOY-XINTEX Automatic/Manual MA Series up to 1800 cu.ft. coverageAED 22,309.00EEPN : 51.09.0007