Webasto BlueCool P Series
Description
Webasto Blue Cool P-Series chiller air conditioning system are equipped with a complete set of outstanding features. To begin with, they include extremely compact dimensions and epoxy painted components that are pre-mounted on one single stainless steel tray.
Benefits Include:
- Wide Product range for medium to large size boats
- Scroll compressors for heavy duty applications
- 208 V, 230 V, and 400 V systems available
- Many customization options with different electronics, tropical versions, vibration dampening and many other features
- Optional heating
- Fully independent cooling circuits
BlueCool P-Series mono compressor |
P30 M |
P36 M |
P42 M |
P48 M |
P60 M |
Weight (kg) |
55 |
66 |
68 |
70 |
75 |
Dimensions (L x W x H) (mm) |
425 x 506 x 547 |
425 x 506 x 547 |
425 x 506 x 547 |
425 x 506 x 547 |
560 x 610 x 602 |
Dimensions (L x W x H) (mm) tropical |
425 x 506 x 547 |
425 x 506 x 547 |
425 x 506 x 547 |
425 x 506 x 547 |
560 x 610 x 602 |
BlueCool P-Series mono compressor |
P72 M |
P84 M |
P96 M |
P112 M |
P126 M |
P143 M |
Weight (kg) |
80 |
85 |
90 |
100 |
110 |
125 |
Dimensions (L x W x H) (mm) |
560 x 610 x 727 |
560 x 610 x 727 |
560 x 615 x 727 |
560 x 811 x 727 |
560 x 811 x 827 |
560 x 845 x 827 |
Dimensions (L x W x H) (mm) tropical |
560 x 610 x 727 |
560 x 610 x 727 |
560 x 615 x 727 |
560 x 811 x 727 |
560 x 811 x 827 |
560 x 845 x 827 |
BlueCool P-Series twin compressors |
P60 T |
P72 T |
P84 T |
P96 T |
P120 T |
Weight (kg) |
90 |
95 |
100 |
130 |
160 |
Dimensions (L x W x H) (mm) |
560 x 660 x 600 |
560 x 694 x 625 |
560 x 694 x 625 |
560 x 683 x 675 |
560 x 790 x 675 |
Dimensions (L x W x H) (mm) tropical |
560 x 660 x 625 |
560 x 694 x 625 |
560 x 694 x 625 |
560 x 683 x 675 |
560 x 790 x 725 |
BlueCool P-Series triple compressors |
P126 R |
P144 R |
P180 R |
P216 R |
P252 R |
Weight (kg) |
180 |
190 |
210 |
250 |
260 |
Dimensions (L x W x H) (mm) |
640 x 1250 x 765 |
640 x 1250 x 765 |
640 x 1250 x 765 |
640 x 1250 x 840 |
640 x 1250 x 840 |
Dimensions (L x W x H) (mm) tropical |
640 x 1250 x 765 |
640 x 1250 x 765 |
640 x 1,250 x 840 |
640 x 1,250 x 840 |
640 x 1,250 x 840 |
BlueCool P-Series quattro compressors |
P120 Q |
P144 Q |
P168 Q |
P192 Q |
P240 Q |
P288 Q |
Weight (kg) |
190 |
210 |
230 |
255 |
270 |
350 |
Dimensions (L x W x H) (mm) |
1,390 x 560 x 640 |
1,390 x 560 x 665 |
1,715 x 560 x 850 |
1,715 x 560 x 850 |
1,715 x 560 x 850 |
1,715 x 560 x 850 |
Dimensions (L x W x H) (mm) tropical |
1,390 x 560 x 665 |
1,390 x 560 x 665 |
1,390 x 560 x 665 |
1,390 x 560 x 715 |
1715 x 560 x 765 |
1,715 x 560 x 850 |
BlueCool P-Series quattro compressors |
P336 Q |
P384 Q |
P448 Q |
P504 Q |
P572 Q |
Weight (kg) |
350 |
450 |
670 |
670 |
725 |
Dimensions (L x W x H) (mm) |
1,715 x 560 x 850 |
2,030 x 635 x 843 |
2,030 x 635 x 918 |
2,030 x 635 x 1,067 |
2,030 x 635 x 1,068 |
Dimensions (L x W x H) (mm) tropical |
1,715 x 560 x 850 |
2,030 x 635 x 843 |
2,030 x 635 x 1,068 |
2,030 x 635 x 1,068 |
2,030 x 635 x 1,068 |
BlueCool P-Series mono compressor |
P30 M |
P36 M |
P42 M |
P48 M |
P60 M |
Cooling capacity* (BTU/h) |
30,000 |
36,000 |
42,000 |
48,000 |
60,000 |
Cooling capacity* (kW) |
8.7 |
10.5 |
12.3 |
14 |
17.6 |
Frequency (Hz)***** |
50/60 |
50/60 |
50/60 |
50/60 |
50/60 |
Current draw running** (A) for 230 V 1-phase |
6.8 |
8 |
9.4 |
12 |
- |
Current draw running** (A) for 400 V 3-phase |
2.9 |
3.5 |
4.1 |
5.1 |
5.9 |
Current draw running FLA**** (A) for 230 V 1-phase |
15 |
17 |
23 |
24 |
- |
Current draw running FLA**** (A) for 400 V 3-phase |
5.1 |
5.6 |
7 |
10 |
11 |
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase |
61 |
76 |
100 |
114 |
- |
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase |
32 |
40 |
46 |
50 |
59 |
Min. chilled water flow (l/min) |
25 |
30 |
33 |
38 |
50 |
Min. seawater flow (l/min) |
19 |
22 |
27 |
30 |
38 |
Recommended seawater pump+ |
WB1000 |
WB1000 |
WB1000 |
WB1000 |
WB1500 |
|
|
|
WB1500 |
WB1500 |
|
Weight (kg) |
55 |
66 |
68 |
70 |
75 |
BlueCool P-Series mono compressor |
P72 M |
P84 M |
P96 M |
P112 M |
P126 M |
P143 M |
Cooling capacity* (BTU/h) |
72,000 |
84,000 |
96,000 |
112,000 |
126,000 |
143,000 |
Cooling capacity* (kW) |
21.1 |
24.6 |
28.1 |
32.8 |
36.9 |
41.8 |
Frequency (Hz)***** |
50/60 |
50/60 |
50/60 |
50/60 |
50/60 |
50/60 |
Current draw running** (A) for 230 V 1-phase |
– |
– |
– |
– |
– |
– |
Current draw running** (A) for 400 V 3-phase |
6.5 |
8.4 |
10 |
11 |
12 |
13 |
Current draw running FLA**** (A) for 230 V 1-phase |
– |
– |
– |
– |
– |
– |
Current draw running FLA**** (A) for 400 V 3-phase |
12 |
15 |
16 |
17 |
20 |
22 |
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase |
– |
– |
– |
– |
– |
– |
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase |
74 |
101 |
95 |
111 |
118 |
118 |
Min. chilled water flow (l/min) |
60 |
66 |
76 |
88 |
104 |
117 |
Min. seawater flow (l/min) |
46 |
56 |
64 |
68 |
82 |
93 |
Recommended seawater pump+ |
WB2500G |
WB2500G |
WB2500G |
WB3000G |
WB3000G |
WB3000G |
|
WB3000G |
WB3000G |
WB3000G |
WB3500 |
WB3500 |
WB3500 |
Weight (kg) |
80 |
85 |
90 |
100 |
110 |
125 |
BlueCool P-Series twin compressors |
P60 T |
P72 T |
P84 T |
P96 T |
P120 T |
Cooling capacity* (BTU/h) |
60,000 |
72,000 |
84,000 |
96,000 |
120,000 |
Cooling capacity* (kW) |
17.6 |
21.1 |
24.6 |
28.1 |
35.2 |
Frequency (Hz)***** |
50/60 |
50/60 |
50/60 |
50/60 |
50/60 |
Current draw running** (A) for 230 V 1-phase |
14 |
16 |
19 |
25 |
– |
Current draw running** (A) for 400 V 3-phase |
5.8 |
7.1 |
8.1 |
10 |
12 |
Current draw running FLA**** (A) for 230 V 1-phase |
30 |
35 |
46 |
47 |
– |
Current draw running FLA**** (A) for 400 V 3-phase |
10 |
11 |
14 |
20 |
22 |
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase |
61 |
76 |
100 |
114 |
– |
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase |
32 |
40 |
46 |
50 |
50 |
Min. chilled water flow (l/min) |
50 |
60 |
66 |
76 |
100 |
Min. seawater flow (l/min) |
38 |
46 |
56 |
64 |
80 |
Recommended seawater pump+ |
WB1500 |
WB2500G |
WB2500G |
WB2500G |
WB3000G |
|
WB2000 |
WB3000G |
WB3000G |
WB3000G |
WB3500 |
Weight (kg) |
90 |
95 |
100 |
130 |
160 |
BlueCool P-Series triple compressors |
P126 R |
P144 R |
P180 R |
P216 R |
P252 R |
Cooling capacity* (BTU/h) |
126,000 |
144,000 |
180,000 |
216,000 |
252,000 |
Cooling capacity* (kW) |
37 |
42.2 |
52.8 |
63.3 |
73.8 |
Frequency (Hz) |
50/60 |
50/60 |
50/60 |
50/60 |
50/60 |
Current draw running** (A) for 230 V 1-phase |
28 |
37 |
– |
– |
– |
Current draw running** (A) for 400 V 3-phase |
12 |
15 |
18 |
20 |
25 |
Current draw running** (A) for 208 V 3-phase |
21 |
26 |
50 |
38 |
72 |
Current draw running FLA **** (A) for 230 V 1-phase |
69 |
71 |
– |
– |
– |
Current draw running FLA **** (A) for 400 V 3-phase |
21 |
30 |
33 |
36.3 |
45 |
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase |
100 |
114 |
– |
– |
– |
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase |
46 |
50 |
59 |
74 |
101 |
Min. chilled water flow (l/min) |
104 |
115 |
138 |
158 |
180 |
Min. seawater flow (l/min) |
82 |
92 |
106 |
125 |
145 |
Recommended seawater pump+ |
WB3000G |
WB3000G |
WB5500 |
WB5500 |
WB5500 |
|
WB3500 |
WB3500 |
|
|
|
Weight (kg) |
180 |
190 |
210 |
250 |
260 |
BlueCool P-Series quattro compressors |
P120 Q |
P144 Q |
P168 Q |
P192 Q |
P240 Q |
P288 Q |
Cooling capacity* (BTU/h) |
120,000 |
144,000 |
168,000 |
192,000 |
240,000 |
288,000 |
Cooling capacity* (kW) |
35 |
42.2 |
49.2 |
56.2 |
70 |
85 |
Frequency (Hz) |
50/60 |
50/60 |
50/60 |
50/60 |
50/60 |
50/60 |
Current draw running** (A) for 230 V 1-phase |
27 |
32 |
38 |
49 |
– |
– |
Current draw running** (A) for 400 V 3-phase |
12 |
14 |
16 |
21 |
23 |
26 |
Current draw running FLA **** (A) for 230 V 1-phase |
59 |
69 |
92 |
94 |
– |
– |
Current draw running FLA **** (A) for 400 V 3-phase |
20 |
22 |
28 |
40 |
44 |
48 |
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase |
61 |
76 |
100 |
114 |
– |
– |
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase |
32 |
40 |
46 |
50 |
59 |
74 |
Min. chilled water flow (l/min) |
100 |
115 |
132 |
161 |
175 |
220 |
Min. seawater flow (l/min) |
80 |
92 |
100 |
115 |
140 |
162 |
Recommended seawater pump+ |
WB3000G |
WB5500 |
WB5500 |
WB5501 |
WB5500 |
WB5500 |
|
WB3500 |
|
|
|
|
WB7400 |
Weight (kg) |
190 |
210 |
230 |
255 |
270 |
350 |
BlueCool P-Series quattro compressors |
P336 Q |
P384 Q |
P448 Q |
P504 Q |
P572 Q |
Cooling capacity* (BTU/h) |
336,000 |
384,000 |
448,000 |
504,000 |
572,000 |
Cooling capacity* (kW) |
99 |
112 |
132 |
148 |
168 |
Frequency (Hz) |
50/60 |
50/60 |
50/60 |
50/60 |
50/60 |
Current draw running** (A) for 230 V 1-phase |
– |
– |
– |
– |
– |
Current draw running** (A) for 400 V 3-phase |
34 |
40 |
43 |
49 |
53 |
Current draw running FLA **** (A) for 230 V 1-phase |
– |
– |
– |
– |
– |
Current draw running FLA **** (A) for 400 V 3-phase |
60 |
64 |
67 |
78 |
89 |
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase |
– |
– |
– |
– |
– |
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase |
101 |
95 |
111 |
118 |
118 |
Min. chilled water flow (l/min) |
245 |
275 |
310 |
360 |
420 |
Min. seawater flow (l/min) |
180 |
200 |
240 |
270 |
325 |
Recommended seawater pump+ |
WB5500 |
WB7400 |
WB7400 |
WB7400 |
WB7400 |
|
WB7400 |
|
WB9800 |
WB9800 |
WB9800 |
Weight (kg) |
350 |
450 |
670 |
670 |
725 |
General note: Values in this table given for 50 Hz only. 60 Hz data available on request.
* BTU/h are based on 7 °C evaporating temperature and 38 °C condensing temperature
** Amperage values for core unit at nominal conditions at 50 Hz
**** FLA (Full Load Amperage) is the current draw at maximum conditions
+ Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow.
++ BlueCool P-Series systems are tested and approved by Webasto for 50/60 Hz operation.
The new professional chiller system for medium to large size boats and super yachts is highly adaptable to the requirements of shipyards and national legislation. In addition to the great cooling capacity, the systems can be individually adapted through various options.
-
Physical Specification
BlueCool P-Series mono compressor
P30 M
P36 M
P42 M
P48 M
P60 M
Weight (kg)
55
66
68
70
75
Dimensions (L x W x H) (mm)
425 x 506 x 547
425 x 506 x 547
425 x 506 x 547
425 x 506 x 547
560 x 610 x 602
Dimensions (L x W x H) (mm) tropical
425 x 506 x 547
425 x 506 x 547
425 x 506 x 547
425 x 506 x 547
560 x 610 x 602
BlueCool P-Series mono compressor
P72 M
P84 M
P96 M
P112 M
P126 M
P143 M
Weight (kg)
80
85
90
100
110
125
Dimensions (L x W x H) (mm)
560 x 610 x 727
560 x 610 x 727
560 x 615 x 727
560 x 811 x 727
560 x 811 x 827
560 x 845 x 827
Dimensions (L x W x H) (mm) tropical
560 x 610 x 727
560 x 610 x 727
560 x 615 x 727
560 x 811 x 727
560 x 811 x 827
560 x 845 x 827
BlueCool P-Series twin compressors
P60 T
P72 T
P84 T
P96 T
P120 T
Weight (kg)
90
95
100
130
160
Dimensions (L x W x H) (mm)
560 x 660 x 600
560 x 694 x 625
560 x 694 x 625
560 x 683 x 675
560 x 790 x 675
Dimensions (L x W x H) (mm) tropical
560 x 660 x 625
560 x 694 x 625
560 x 694 x 625
560 x 683 x 675
560 x 790 x 725
BlueCool P-Series triple compressors
P126 R
P144 R
P180 R
P216 R
P252 R
Weight (kg)
180
190
210
250
260
Dimensions (L x W x H) (mm)
640 x 1250 x 765
640 x 1250 x 765
640 x 1250 x 765
640 x 1250 x 840
640 x 1250 x 840
Dimensions (L x W x H) (mm) tropical
640 x 1250 x 765
640 x 1250 x 765
640 x 1,250 x 840
640 x 1,250 x 840
640 x 1,250 x 840
BlueCool P-Series quattro compressors
P120 Q
P144 Q
P168 Q
P192 Q
P240 Q
P288 Q
Weight (kg)
190
210
230
255
270
350
Dimensions (L x W x H) (mm)
1,390 x 560 x 640
1,390 x 560 x 665
1,715 x 560 x 850
1,715 x 560 x 850
1,715 x 560 x 850
1,715 x 560 x 850
Dimensions (L x W x H) (mm) tropical
1,390 x 560 x 665
1,390 x 560 x 665
1,390 x 560 x 665
1,390 x 560 x 715
1715 x 560 x 765
1,715 x 560 x 850
BlueCool P-Series quattro compressors
P336 Q
P384 Q
P448 Q
P504 Q
P572 Q
Weight (kg)
350
450
670
670
725
Dimensions (L x W x H) (mm)
1,715 x 560 x 850
2,030 x 635 x 843
2,030 x 635 x 918
2,030 x 635 x 1,067
2,030 x 635 x 1,068
Dimensions (L x W x H) (mm) tropical
1,715 x 560 x 850
2,030 x 635 x 843
2,030 x 635 x 1,068
2,030 x 635 x 1,068
2,030 x 635 x 1,068
-
Technical Specification
BlueCool P-Series mono compressor
P30 M
P36 M
P42 M
P48 M
P60 M
Cooling capacity* (BTU/h)
30,000
36,000
42,000
48,000
60,000
Cooling capacity* (kW)
8.7
10.5
12.3
14
17.6
Frequency (Hz)*****
50/60
50/60
50/60
50/60
50/60
Current draw running** (A) for 230 V 1-phase
6.8
8
9.4
12
-
Current draw running** (A) for 400 V 3-phase
2.9
3.5
4.1
5.1
5.9
Current draw running FLA**** (A) for 230 V 1-phase
15
17
23
24
-
Current draw running FLA**** (A) for 400 V 3-phase
5.1
5.6
7
10
11
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase
61
76
100
114
-
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase
32
40
46
50
59
Min. chilled water flow (l/min)
25
30
33
38
50
Min. seawater flow (l/min)
19
22
27
30
38
Recommended seawater pump+
WB1000
WB1000
WB1000
WB1000
WB1500
WB1500
WB1500
Weight (kg)
55
66
68
70
75
BlueCool P-Series mono compressor
P72 M
P84 M
P96 M
P112 M
P126 M
P143 M
Cooling capacity* (BTU/h)
72,000
84,000
96,000
112,000
126,000
143,000
Cooling capacity* (kW)
21.1
24.6
28.1
32.8
36.9
41.8
Frequency (Hz)*****
50/60
50/60
50/60
50/60
50/60
50/60
Current draw running** (A) for 230 V 1-phase
–
–
–
–
–
–
Current draw running** (A) for 400 V 3-phase
6.5
8.4
10
11
12
13
Current draw running FLA**** (A) for 230 V 1-phase
–
–
–
–
–
–
Current draw running FLA**** (A) for 400 V 3-phase
12
15
16
17
20
22
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase
–
–
–
–
–
–
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase
74
101
95
111
118
118
Min. chilled water flow (l/min)
60
66
76
88
104
117
Min. seawater flow (l/min)
46
56
64
68
82
93
Recommended seawater pump+
WB2500G
WB2500G
WB2500G
WB3000G
WB3000G
WB3000G
WB3000G
WB3000G
WB3000G
WB3500
WB3500
WB3500
Weight (kg)
80
85
90
100
110
125
BlueCool P-Series twin compressors
P60 T
P72 T
P84 T
P96 T
P120 T
Cooling capacity* (BTU/h)
60,000
72,000
84,000
96,000
120,000
Cooling capacity* (kW)
17.6
21.1
24.6
28.1
35.2
Frequency (Hz)*****
50/60
50/60
50/60
50/60
50/60
Current draw running** (A) for 230 V 1-phase
14
16
19
25
–
Current draw running** (A) for 400 V 3-phase
5.8
7.1
8.1
10
12
Current draw running FLA**** (A) for 230 V 1-phase
30
35
46
47
–
Current draw running FLA**** (A) for 400 V 3-phase
10
11
14
20
22
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase
61
76
100
114
–
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase
32
40
46
50
50
Min. chilled water flow (l/min)
50
60
66
76
100
Min. seawater flow (l/min)
38
46
56
64
80
Recommended seawater pump+
WB1500
WB2500G
WB2500G
WB2500G
WB3000G
WB2000
WB3000G
WB3000G
WB3000G
WB3500
Weight (kg)
90
95
100
130
160
BlueCool P-Series triple compressors
P126 R
P144 R
P180 R
P216 R
P252 R
Cooling capacity* (BTU/h)
126,000
144,000
180,000
216,000
252,000
Cooling capacity* (kW)
37
42.2
52.8
63.3
73.8
Frequency (Hz)
50/60
50/60
50/60
50/60
50/60
Current draw running** (A) for 230 V 1-phase
28
37
–
–
–
Current draw running** (A) for 400 V 3-phase
12
15
18
20
25
Current draw running** (A) for 208 V 3-phase
21
26
50
38
72
Current draw running FLA **** (A) for 230 V 1-phase
69
71
–
–
–
Current draw running FLA **** (A) for 400 V 3-phase
21
30
33
36.3
45
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase
100
114
–
–
–
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase
46
50
59
74
101
Min. chilled water flow (l/min)
104
115
138
158
180
Min. seawater flow (l/min)
82
92
106
125
145
Recommended seawater pump+
WB3000G
WB3000G
WB5500
WB5500
WB5500
WB3500
WB3500
Weight (kg)
180
190
210
250
260
BlueCool P-Series quattro compressors
P120 Q
P144 Q
P168 Q
P192 Q
P240 Q
P288 Q
Cooling capacity* (BTU/h)
120,000
144,000
168,000
192,000
240,000
288,000
Cooling capacity* (kW)
35
42.2
49.2
56.2
70
85
Frequency (Hz)
50/60
50/60
50/60
50/60
50/60
50/60
Current draw running** (A) for 230 V 1-phase
27
32
38
49
–
–
Current draw running** (A) for 400 V 3-phase
12
14
16
21
23
26
Current draw running FLA **** (A) for 230 V 1-phase
59
69
92
94
–
–
Current draw running FLA **** (A) for 400 V 3-phase
20
22
28
40
44
48
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase
61
76
100
114
–
–
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase
32
40
46
50
59
74
Min. chilled water flow (l/min)
100
115
132
161
175
220
Min. seawater flow (l/min)
80
92
100
115
140
162
Recommended seawater pump+
WB3000G
WB5500
WB5500
WB5501
WB5500
WB5500
WB3500
WB7400
Weight (kg)
190
210
230
255
270
350
BlueCool P-Series quattro compressors
P336 Q
P384 Q
P448 Q
P504 Q
P572 Q
Cooling capacity* (BTU/h)
336,000
384,000
448,000
504,000
572,000
Cooling capacity* (kW)
99
112
132
148
168
Frequency (Hz)
50/60
50/60
50/60
50/60
50/60
Current draw running** (A) for 230 V 1-phase
–
–
–
–
–
Current draw running** (A) for 400 V 3-phase
34
40
43
49
53
Current draw running FLA **** (A) for 230 V 1-phase
–
–
–
–
–
Current draw running FLA **** (A) for 400 V 3-phase
60
64
67
78
89
Locked Rotor Amperage LRA (A) for Single compressor 230 V 1-phase
–
–
–
–
–
Locked Rotor Amperage LRA (A) for Single compressor 400 V 3-phase
101
95
111
118
118
Min. chilled water flow (l/min)
245
275
310
360
420
Min. seawater flow (l/min)
180
200
240
270
325
Recommended seawater pump+
WB5500
WB7400
WB7400
WB7400
WB7400
WB7400
WB9800
WB9800
WB9800
Weight (kg)
350
450
670
670
725
General note: Values in this table given for 50 Hz only. 60 Hz data available on request.
* BTU/h are based on 7 °C evaporating temperature and 38 °C condensing temperature
** Amperage values for core unit at nominal conditions at 50 Hz
**** FLA (Full Load Amperage) is the current draw at maximum conditions
+ Recommendation only. Pump size shall be adapted to application constraints in order to always ensure minimal sea water flow.
++ BlueCool P-Series systems are tested and approved by Webasto for 50/60 Hz operation.
-
General Specification
The new professional chiller system for medium to large size boats and super yachts is highly adaptable to the requirements of shipyards and national legislation. In addition to the great cooling capacity, the systems can be individually adapted through various options.
Product Options
Product | OEM | EEPN | Availability | Price | Qty |
---|---|---|---|---|---|
51.60.0007
|
51.60.0007
|
On Request
|
|